| AP3-Series
10-400KVA On-line Double Conversion Three Phase UPS / Inverter
/Frequency Converter Full Digitalized Intelligent Galvanic Isolation
Design |
| Features |
Advanced Technology DSP IGBT Components
Wide Input Range, Robust Design For Harsh Environment
Multi-CPU and Software/Hardware Cooperate Control
DC Start Function, Can be Started without AC
True Galvanic Isolation Design
Modular Design for Easy Maintenance and Minimize MTTR
Intelligent, Safe and Unique Battery Management System
Variety of Accessory
Parallel Operation
Specifications Can be Customized
|
| Advantages |
Advanced technology DSP, IGBT and
switching components:
To increase the reliability and efficiency. |
True Galvanic isolation design:
An isolated transformer is put at the output, can solve the
problem of poor input grounding, can accept a different ground
between input and output and can avoid the annoying problem
of ground leakage current. The user gets the bonus of attenuation
of common mode noise from the output isolation transformer. |
Multi-CPU design and
software/hardware cooperate control:
Several CPUs are employed in the control circuit, critical functions
are designed to parallel redundancy to improve reliability. |
Redundant power supply:
An extra power supply is connected redundantly to supply power
of the static switch, so that, there will be AC output no matter
what happen to the UPS. |
Plug & play modular design:
The power circuit is separated into several modules plugged
into slats in the UPS, which is easy to pull out, perms quick
maintenance and easier trouble-shooting. Therefore, it can be
regarded plug and play modules. |
Each phase with individual inverter
supporting:
Characteristics will not be violated under 100% unbalance load. |
Protection against detaching and
floating of the neutral of input power supply:
MOV (surge protector) is added at the input, provide sufficient
protection to both UPS and the load from any lighting or surge
caused by neighboring large loads. |
User friendly control design:
UPS is designed with breaker on/off sensor, power supply sensor
etc.. Therefore, any operational mistake made by the user causes
no harm to the UPS. |
Intelligent charger with temperature
compensation:
To improve the battery life expectancy |
Huge charging power (selectable):
The charge power is selectable (Lo/Me/Hi) according to Ah of
the battery, and can charge up battery of more than 8 Has back-up
time without adding extra charger. |
Intelligent, safe battery test
circuitry:
Battery is tested after every boost charge of battery (either
initiated by battery discharge or by one month has elapsed)
without stopping the rectifier. II prevents the risk of output
AC (allure in case of battery bad and can inform the user the
battery condition. |
Intelligent fan speed control:
Fans will slow down under light load. so that the life expectancy
of the fans is longer than a is specified MTBF of fans are extended |
Reasonable heat evacuation passage
design:
Control circuitry and power circuitry are physically separated
Therefore the UPS system can operate under harsh environment. |
DC start function:
The UPS can be started without AC source, that is, can be started
with battery only, because current limit circuitry is added.
It can prevent the problem of many UPS that the big inrush current
blow the battery fuse and hurts the DC capacitor when battery
is
connected to empty DC bus (before the DC bus is energized). |
Various interface options:
Remote control panel, 3 phases software for PC monitoring, auto
dialing module, battery monitoring module, 3 phases SNMP card,
and emergent stop switch are available. |
12-Pulse Full Controlled Rectifier
(option):
In order to further improve the power factor and reduce harmonic
current drawn by the rectifier, our UPS from 100KVA and above
use the 12-pulse full controlled rectifier. The total current
harmonic current can be reduced to around 10%, and power factor
is improved to over 0.8. A phase shift transformer is added
to achieve the performance. The input inductor is retained too
to obtain the best result. Although the cost is higher, it is
more reliable and rugged topology. The user needs not to increase
the input breaker and cable, input KVA and harmonic current
drawn is minimized to fulfill the worldwide energy saving requirements. |
Parallel Operation (option):
To increase the capacity and reliability. Load is equally shared
between paralleled units. When one of the units has problem,
the other units continue running without output interruption.
No site adjustment is required. |
| Other |
UPSCANTTM - Remote Control
Penal
A hand held display module with LCD and LED can monitor 1 -
99 UPSs with RS-085 connected in series from distance < 1000M. |
UPSCOMTM - PC Monitoring
Software
Can provide real-time three phases information of UPS connected
on the line and monitor several Li with one PC. |
DCMANTM -Battery Monitoring
Module
An intelligent module to keep watching each battery in a battery
bank connected in series and can distinguish and repair the
aged battery before it is seriously worn out. |
SNMP/HTTP agent
Can monitor and manage the UPS through Web browser and Java
apples, providing simultaneously three phases data acquisition.
|
Emergency Stop Switch
In case of hazard, for example, electric shock, fire or earthquake,
the UPS can be shutdown (Will have no AC at the output) either
through a switch (can be added upon request) or through smoke
detector signal (can be added upon request) to prevent further
injuries or destruction |
| PHASE |
3 Phase
Input / 3 Phase Output |
| KVA |
10 |
20 |
30 |
40 |
50 |
60 |
80 |
100 |
120 |
160 |
240 |
320 |
400 |
| INPUT (RECTIFIER) |
| Input Voltage |
190V / 208V / 380V / 400V
/ 415V / 440V / 480V / 600V, 3P4W a 3P3W |
| Input Range |
+/-20% (> +/-L20% is
available upon request) |
| Input Frequency |
50 / 60 Hz + / -5Hz |
| Power Walk In |
0% -100 : 20 sec |
| Efficiency |
>98% |
| Voltage Regulation |
+ / -1% |
| BATTERY |
| Battery Type / Pcs |
Maintenance free lead acid
batteries / 12V x 29pcs |
| Maximum Charge Current Adc (Selcetable) |
5 |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
80 |
120 |
160 |
20 |
| Battery Start |
Yes, UPS can be started without
AC source. |
| INVERTER |
| Output Voltage, Regulation |
190V / 208V / 380V / 400V
/ 415V / 440V / 480V / 600V, 3P4W or 3P3W + / -1% |
| Wave Form |
Sine Wave |
| Output Power Factor |
0.8 |
| Frequency Lock Range |
50 / 60 Hz + / - 3Hz |
| Output Frequency (Free Running) |
50 / 60 Hz + / - 0.1Hz |
| Phase Shift Under 100% Unbalance
Load |
< 0.5° |
| THD (Linear Load) |
< 2% |
| Overload |
<110% |
Continuous |
| 110-125% |
15 minutes |
| 125-150% |
10 minutes |
| >150% |
30 seconds |
| Efficiency (100% Load) |
93% |
93.5% |
94% |
94.5% |
95% |
| STATIC SWITCH |
| Voltage Range |
173-277 VAC (L-N) |
Mains Inverter |
0 ms |
| OVERALL CHARACTERISTICS |
| Overall Efficiency |
91% |
91.5% |
92% |
92.5% |
93% |
| Maximum Heat Dissipations (Kw) |
1.1 |
1.3 |
1.9 |
2.6 |
3 |
3.5 |
4.6 |
5.4 |
6.5 |
8.7 |
13 |
17.4 |
21.7 |
| Width x Height x Depth (mm) |
550 x 1600 x 800 |
1100 x 1600 x 800 |
2200 x 1600 x 800 x 3300
x 1600 x 800(400K) |
| Weight (Kg. without battery) |
270 |
300 |
400 |
480 |
550 |
680 |
820 |
950 |
1180 |
1450 |
2900 |
3100 |
3500 |
| Audible Noise |
< 65 dBA (At 1 M) |
< 67 dBA (At 1 M) |
< 70 dBA (At 1 M) |
| Temperature / Humidity |
0-40 degree C ; 32-104degree
F ; 0% - 90% (Non-Condensing) |
| Altitude |
< 1500 M Above Sea Level |
| FCC CLASS A, EN50091-1,-2 |
YES |
| Short Circuit Pretection |
Rectifier, Reserve, and Bypass |
| Lightning / EMC Filter |
MOV / Input & Output |
| Galvanic Isolation |
Input & Output true Galvanic
isolation |
| Indicator & Alarm |
LCD, LED, Mimic Display,
Buzzer |
| Remote Control / Communication
Interface |
Monitoring 1-99 UPS simultaneously
/ Dry contact, RS232, RS485 |